Vol. 3, No. 4, pp. 706-722(2007)
FLEXURAL BEHAVIOUR OF SFRC IN-FILLED LIGHT GAUGE STEEL RECTANGULAR BOX SECTIONS
S. Senthil Selvan 1,*, K. Nagamani 2 and E. Chandrasekaran 3
1Senior Lecturer, Department of Civil Engineering, B.S.A Crescent Engineering College, Chennai, India
* (Corresponding author: E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.)
2Professor, Structural Engineering Division, College of Engineering, Anna University, Chennai, India
3Professor, Department of Civil Engineering, B.S.A Crescent Engineering College, Chennai, India
Received: 4 December 2006; Revised: 10 April 2007; Accepted: 20 April 2007
View Article | Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
This paper presents an experimental study on the flexural behaviour of plain cement concrete (PCC) and steel fiber reinforced concrete (SFRC) in-filled light gauge steel rectangular box sections under pure bending. Concrete in-fill provides internal support to the section and delays local buckling. It also contributes to the inertia of the section which increases the flexural strength and stiffness of the member. A reference hollow beam, plain concrete in-filled and SFRC in-filled (with three different volume fraction of fibers) beams are tested up to failure in pure bending with respect to their principal axes. Extensive strain and deformation measurements are taken at compression and tension zones. It is found that the SFRC in-filled sections take more load than hollow and plain concrete in-filled beams when it is subjected to loads about their major and minor axes. In this experimental study, it is observed that SFRC in-filled beams with 1% volume fraction of fibers have enhanced structural properties much more than other types of beams. The moment - strain plots show, a good ductility performance by the hollow and SFRC in-filled beams compared to the plain concrete in-filled beams. A comparison of the observed moment capacities and flexural stiffnesses is made, with the values calculated using the expressions recommended by the various codes of practice such as AIJ, BS 5400, Eurocode 4 & LRFD. It was found that the values predicted by the AIJ code agree reasonably well with the experimental results. The codes developed for ordinary cement concrete in-filled beams require modifications when they are applied to high performance concretes such as SFRC in-filled composite beams.
KEYWORDS
Hollow; PCC and SFRC in-filled beams; pure bending; flexural stiffness; flexural strength; ductility
REFERENCES
[1] Kas, S., Ge, H. and Usami, T.A., “Capacity Prediction Procedure for Concrete-filled Steel Columns”, Journal of Earth quake Engineering, 2001, Vol. 4, No. 5, pp. 483-520.
[2] Architectural Institute of Japan, “Recommendations for Design and Construction of Concrete Filled Steel Tubular Structures”, Architectural Institute of Japan, Tokyo, 1997.
[3] BS 5400. Part 5, “Concrete and Composite Bridges”, British Standard Institution, 1979.
[4] Eurocode 4, “Deign of Composite Steel and Concrete Structures, Part 1.1: General Rules and Rules for Buildings (Together with United Kingdom National Application Document), DD ENV 1994-1-1: 1994 London W1A2BS”, British Standard Institution, 1994.
[5] AISC-LRFD, “Load and Resistance Factor Design Specification for Structural Steel Buildings”, American Institute of Steel Construction Inc., 1999.
[6] Hajjar, J., “Concrete-filled Steel Tube Columns under Earthquake Loads”, Journal of Progress Structural Engineering Materials, 2000, Vol. 2, No. 1, pp. 1-10.
[7] Fukumoto, Y. “Structural Stability Design, Steel and Composite Structures”, Oxford: Pergamon, 1997.
[8] Elchalakani, M., Zhao, X.L. and Grzebieta, R.H., “Concrete-filled Circular Steel Tubes Subjected to Pure Bending”, Journal of Constructional Steel Research, 2001, Vol. 57, No. 11, pp. 1141-1168.
[9] Gho, W.M. and Liu, D., “Flexural Behaviour of High-strength Rectangular Concrete-filled Steel Hollow Sections”, Journal of Constructional Steel Research, 2004, Vol. 60, No. 11, pp 1681-1696.
[10] Fam, A.Z. and Rizkalla, S.H., “Flexural Behaviour of Concrete-filled Fiber-reinforced Polymer Circular Tubes”, Journal of Composites for Construction, 2002, Vol. 6, No. 2, pp. 123-132.
[11] Han, L.H., “Flexural Behaviour of Concrete-filled Steel Tubes”, Journal of Constructional Steel Research, 2004, Vol. 60, No. 2, pp. 313-337.
[12] Han, L.H, Lu, H., Yao, G.H. and Liao, F.Y., “Further Study on the Flexural Behaviour of Concrete-filled Steel Tubes”, Journal of Constructional Steel Research, 2006, Vol. 62, No. 6, pp. 554-565.
[13] Helena, J.H. and Knight, S.G..M., Behaviour of Cold-formed Steel In-filled Columns”, Journal of Steel and Composite Structures, 2005, Vol. 5, No. 1, pp. 35-47.
[14] Senthil, S. S., Chandrasekaran, E., Srinivasaraghavan, R. and Nagamani, K., “Post Buckling Strength of Steel Fiber Reinforced Concrete In-filled Light Gauge Steel Box Sections - An Experimental Study”, Proceedings of the 2005 Annual Stability Conference, 2005, Structural Stability Research Council, University of Missouri – Rolla, Canada Vol. 1, pp, 389-407.
[15] Mursi, M. and Uy, B., “Strength of Slender Concrete Filled High Strength Steel Box Columns”, Journal of Constructional Steel Research, 2004, Vol. 60, No. 12, pp. 1825-1848.
[16] Liu, D., “Behaviour of High Strength Rectangular Concrete-filled Steel Section Columns under Eccentric Loading”, Journal of Thin Walled Structures, 2004, Vol. 42, No. 12, pp. 1631-1644.
[17] Liu, D., Gho, W.M. and Yuan, J, “Ultimate Capacity of High Strength Rectangular Concrete Filled Steel Hollow Section Stub Columns”, Journal of Constructional Steel Research, 2003, Vol. 59, No. 12, pp. 1499-1515.
[18] Standard Practice for Selecting Proportions for Normal, Heavyweight, and Mass Concrete. ACI 211.1-91. ACI Manual of Concrete 1991, Part 1, Materials and General Properties of Concrete. Detroit, Michigan: American Concrete Institute.
[19] Giakoumelis, G and Lam, D., “Axial Capacity of Circular Concrete–filled Tube Columns”, Journal of Constructional Steel Research, 2004, Vol. 60, No. 7, pp. 1049-1068.
[20] ASTM, “American Society for Testing and Materials. Test Methods for Tension Testing of Metallic Materials”, West Conshohocken, PA, 1997.
[21] IS: 456 – 2000, “Indian Standard Code of Practice for Plain and Reinforced Concrete (Fourth Revision)”, Bureau of Indian Standards, 2000.