Advanced Steel Construction

Vol. 17, No. 1, pp. 84-94 (2021)


ENHANCING COLLAPSE-RESISTANCE OF STEEL FRAME

JOINTS BASED ON FOLDED AXILLARY PLATES

 

Bao Meng 1, 2, Liang-De Li 1, Wei-Hui Zhong 1, *, Ji-Ping Hao 1 and Zheng Tan 1

1 School of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an 710055, China

2 Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education (XAUAT), Xi’an 710055, China

*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)

Received: 9 June 2020; Revised: 30 November 2020; Accepted: 2 December 2020

 

DOI:10.18057/IJASC.2021.17.1.10

 

View Article   Export Citation: Plain Text | RIS | Endnote

ABSTRACT

To address the limited anti-collapse ability of traditional rigid connections under progressive collapse, this study improves upon the traditional fully welded connection based on folded axillary plates. These folded axillary plates were arranged on the outer side of the beam-end flanges. The movement mechanisms of the tension and compression folded axillary plates under progressive collapse were revealed based on theoretical analysis. Using the validated numerical model, the performance against progressive collapse and key parameters of the improved connection were discussed in detail. No significant effects were observed on the stress of the structure, given the small deformation, and the ultimate deformation and resistance of the steel structure could be significantly improved in later stages. Subsequently, the catenary mechanism in the beam was fully developed, and the beam member was fully utilized. The failure sequence of the substructure with folded axillary plates first involved the folded axillary plate on the tension side gradually straightening, followed by the two plastic regions forming at the beam flange. Afterward, either the tension beam flange at the beam root and the folded axillary plate broke successively or the tension beam flange broke at the point where the plastic hinge moved outward. Additionally, the anti-progressive collapse design process for the folded axillary plate and the design parameters were suggested following theoretical and numerical analyses.

 

KEYWORDS

Steel frame, Folded axillary plate, Rigid connection, Collapse-resistance, Numerical analysis


REFERENCES

[1] The building regulations 2000, Part A, Schedule 1: A3, Disproportionate collapse, Office of the Deputy Prime Minister, London, 2004.

[2] EN 1991-1-7., Eurocode 1: Actions on structures. Part 1-7: General Ac-tions-Accidental actions (CEN 2006), European Committee for Standardization, Brussels, 2006.

[3] GSA 2013. Alternate path analysis and design guidelines for progressive collapse resistance, United States General Services Administration, Washington, D.C., USA, 2013.

[4] UFC 4-023-03. Design of structures to resist progressive collapse, Department of Defense, Washington, D.C., USA, 2013.

[5] Japanese Society of Steel Urban Construction Council on Tall Buildings and Urban Habitat. Guidelines for Collapse Control Design-Construction of Steel Buildings with High Redundancy, Tokyo, Japan, 2004.

[6] Yu J. and Tan K.H, “Special detailing techniques to improve structural resistance against progressive collapse”, Journal of Structural Engineering, 140 (3): 04013077, 2014.

[7] Wang W. and Qin X., “Retrofitted connection details of through diaphragm joint for structural robustness enhancement”, Journal of Tongji University (Natural Sci-ence), 43(5): 685-692, 2015.

[8] Meng B., Zhong W.H., Hao J.P., et al., “Improved steel frame performance against progressive collapse with infill panels”, Journal of Constructional Steel Research, 158: 201-212, 2019.

[9] Vasdravellis G., Baiguera M., Al-Sammaraie D., “Robustness assessment of a steel self-centering moment-resisting frame under column loss”, Journal of Construc-tional Steel Research, 141: 36-49, 2018.

[10] Wei J.P., Tian L.M., Hao J.P., et al., “Novel principle for improving performance of steel frame structures in column-loss scenario”, Journal of Constructional Steel Research, 163: 105768, 2019.

[11] Qiang H.L., Yang J.X., Feng P., et al., “Kinked rebar configurations for improving the progressive collapse behaviours of RC frames under middle column removal scenarios”, Engineering Structures, 211: 110425, 2020.

[12] Qiu L., Lin F., Wu K.C., “Improving progressive collapse resistance of RC beam–column subassemblages using external steel cables”, Journal of Performance of Constructed Facilities, 34(1): 04019079, 2020.

[13] Gao S., Guo L.H., Zhang S.M., “Study on anti-collapse performance of semi-rigid composite joint strengthened by steel plate considering material damage”, Journal of Building Structures, 40(3): 240-246, 2019.

[14] Lu X.Z., Zhang L., Lin K.Q., et al., “Improvement to composite frame systems for seismic and progressive collapse resistance”, Engineering Structures, 170: 106119, 2020.

[15] Meng B., Zhong W.H., Hao J.P., et al., “Improving anti-collapse performance of steel frame with RBS connection”, Journal of Constructional Steel Research, 158: 201-212, 2019.

[16] Lew H.S., Main J.A., Robert S.D., et al., “Performance of steel moment connections under a column removal scenario. I: Experiments”, Journal of Structural Engineer-ing, 139(1): 98-107, 2013.

[17] Li L. Behavior of steel beam-to-column connections in structural progressive collapse, D.E., Tongji University, Shanghai, China, 2014.

[18] Meng B., Zhong W.H., Hao J.P., “Anti-collapse performances of steel beam-to-column assemblies with different span ratios”, Journal of Constructional Steel Research, 140(1): 125-138, 2018.

[19] Dinu F., Marginean I., Dubina D., “Experimental testing and numerical modelling of steel moment-frame connections under column loss”, Engineering Structures, 151: 861-878, 2017.

[20] Stylianidis P.M., Nethercot D.A., “Modeling of connection behaviour for progres-sive collapse analysis”, Journal of Constructional Steel Research, 113(6): 169-184, 2015.

[21] Yang B., Tan K.H., Xiong G., et al., “Experimental tests of different types of bolted steel beam-column joints under a central-column-removal scenario”, Journal of Constructional Steel Research, 121: 341-351, 2016.

[22] Yang B., Tan K.H., “Experimental study about composite frames under an internal column-removal scenario”, Engineering Structures, 54: 112-30, 2013.

[23] Meng B., Zhong W.H., Hao J.P., et al., “Calculation of the resistance of an unequal span steel substructure against progressive collapse based on the component method”, Engineering Structures, 182: 13-28, 2019.

[24] FEMA-267. Interim guidelines: evaluation, repair, modification and design of welded steel moment frames, Federal Emergency Management Agency, Washington, D.C.,1995.

[25] Sadek F., Main J.A., Lew H.S., et al., “An experimental and computational study of steel moment connections under a column removal scenario, NIST 1669” , National Institute of Standards and Technology, 2010.

[26] ABAQUS Analysis User’s Manual, 6.17, ABAQUS, Inc., Dassault Systemes. USA, 2017.

[27] Yang B. and Tan K.H., “Numerical analyses of steel beam-column joints subjected to catenary action”, Journal of Constructional Steel Research, 70 (3): 1-11, 2012.

[28] Yang B., Tan K.H., Xiong G., “Behaviour of composite beam–column joints under a middle-column-removal scenario: Component-based modelling”, Journal of Con-structional Steel Research, 104:137-154, 2015.

[29] Jiang L., Wang X.L., Yang W.W., “Stress analysis of beam-column joint with dif-ferent web corner cutting forms”, Journal of Lanzhou University of Technology, 39(2): 106-109, 2013.

[30] Zhou T.H., Li W.C., Guan Y., et al., “Damage analysis of steel frames under cyclic load based on stress triaxiality”, Engineering Mechanics, 31(7): 146-155, 2014.

[31] GB 50017-2017. Standard for design of steel structures, China Architecture & Building Press, Beijing, China, 2017.