Vol. 17, No. 3, pp. 221-230 (2021)
HYSTERETIC PERFORMANCE OF WEAK-AXIS CONNECTION
WITH I-SHAPED PLATES IN STEEL FRAME
Ying-Lu Xu 1, 2, 3, * and Ji-Ping Hao 1, 2, 3
1 School of Civil Engineering, Xi’an University of Architecture & Technology, Xi’an, 710055, China
2 Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education(XAUAT), Xi’an, 710055, China
3 Shaanxi Key Lab of Structure and Earthquake Resistance(XAUAT), Xi’an, 710055, China
* (Corresponding author: E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 6 April 2020; Revised: 14 January 2021; Accepted: 27 January 2021
DOI:10.18057/IJASC.2021.17.3.1
![]() |
Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
This paper elucidates numerically the behavior of weak-axis moment connections proposed by welding I-shaped plates in the H-section column to increase connection strength and ductility in steel frame. After validating the numerical methods through comparing the results of numerical analysis and experiments, the effectiveness of the proposed weak-axis connection were examined through comparing to the traditional weak-axis connection. The proposed weak-axis connection could move the highest stresses away from the start-stop points of a weld, and thus preventing the premature brittle fracture of the beam flange welds. The plastic hinge formed away from the beam-column interface, while the local buckling occurred in the weld access holes region in the traditional weak-axis connection. The proposed weak-axis connections can be classified as rigid in a strong-bracing system, and be classified as semi-rigid in weak-supported or unsupported system. And then a series of parametric studies was conducted to better understand the behavior of proposed weak-axis moment connections. The force-displacement relationships, location of the plastic hinge, Mises index (MI), triaxiality index (TI) and rupture index (RI) distributions at the beam flange welds were reported in detail. According to the numerical analysis, the design variables of I-shaped plates and widened flange plate are suggested, along with a design procedure.
KEYWORDS
Steel frame, Moment connections, Weak-axis, I-shaped plates, Cyclic performance
REFERENCES
[1] T. Kim, A.S. Whittaker, A.S.J. Gilani, et al., Cover-plate and flange-plate steel moment-resisting connections, J. Struct. Eng. ASCE 128 (2002) 474-482.
[2] C.H. Lee, J.H. Jung, M.H. Oh, et al., Cyclic seismic testing of steel moment connections reinforced with welded straight haunch, Eng. Struct. 25 (2003) 1743-1753.
[3] C.C. Chen, C.C. Lin, Seismic performance of steel beam-to-column moment connections with tapered beam flanges, Eng. Struct. 48 (2013) 588-601.
[4] X. Chen, G. Shi, Experimental study on seismic behavior of cover-plate joints in high strength steel frames, Eng. Struct. 191 (2019) 292-310.
[5] J. Jin, S. EI-Taxil, Seismic performance of steel frames with reduced beam section connections, J. Constr. Steel Res. 61 (2005) 453-471.
[6] S.L. Jones, G.T. Fry, M.D. Engelhardt, Experimental evaluation of cyclically loaded reduced beam section moment connections, J. Struct. Eng. ASCE 128 (2002) 441–451.
[7] D.T. Pachoumis, E.G. Galoussis, C.N. Kalfas, et al., Cyclic performance of steel moment-resisting connections with reduced beam sections-experimental analysis and finite element model simulation, Eng. Struct. 32 (2010) 2683-23102.
[8] S. Momenzadeh, M.T. Kazemi, M.H. Asl, Seismic performance of reduced web section moment connections, Int. J. Steel Struct. 17 (2017) 413-425.
[9] C.S. Gilton, C.M. Uang, Cyclic response and design recommendations of weak-axis reduced beam section moment connections, J. Struct. Eng. ASCE 128 (2002) 452-463.
[10] FEMA-355D State of the art report on connection performance, Federal Emergency Management Agency, Washington, DC, 2000.
[11] B.S. Guo, Hysteretic behavior and design criterion of beam-to-column web connections in steel moment frames under cyclic load, Xi’an University of Architecture & Technology, Xi’an, 2004. (in Chinese)
[12] Y.S. Yu, J. Wang, W.P. Huang, et al., Experimental study on the failure mode of reduced beam section connections of the bolted-welded connection of steel frame beam-column about minor axis, Building Structure, 44 (2014) 30-33. (in Chinese)
[13] K. Oh, K. Lee, L. Chen, et al., Seismic performance evaluation of weak-axis column-tree moment connections with reduced beam section, J. Constr. Steel Res. 105 (2015) 28-38.
[14] S.D. Kim, S.S. Kim, Y.K. Ju, Strength evaluation of beam-column connection in the weak axis of H-shaped column, Eng. Struct. 30 (2008) 1699-1710.
[15] W.L. Li, J.P. Hao, L.K. Wang, et al., Experimental and analytical study on stiffness of beam-to-column minor axis top-and seat angle connection in steel frames, Journal of Building Structures, 29 (2008) 125-131.
[16] Z. Wang, T. Wang, Experimental and finite element analysis for the end plate minor axis connection of semi-rigid steel frames, China Civil Engineering Journal, 45 (2012) 83-89.
[17] L.F. Lu, Y.L. Xu, H. Zheng. Investigation of composite action on seismic performance of weak-axis column bending connections, J. Constr. Steel Res. 129 (2017) 286-300.
[18] ANSI/AISC 341-10 Seismic provisions for structural steel buildings, AISC, Chicago, 2010.
[19] Eurocode 3 Design of steel Structures Part 1-8: Design of joints, London, 2003.
[20] G. Shi, F. Yuan, D. Huo, et al., The theoretical model and measuring calculation method of the beam-to-column joint rotation in steel frame, Engineering Mechanics, 29 (2012) 52-60. (in Chinese)
[21] GB 50011-2010 Code for seismic design of buildings, China Architecture & Building Press, Beijing, 2010. (in Chinese)
[22] S. El-Tawil, T. Mikesell, E. Vidarsson, et al., Strength and ductility of FR welded-bolted connection, SAC Rep. No. 108-01, SAC Joint Venture, Sacramento, Calif, 1998.
[23] F. Hu, G. Shi, B. Yu, et al., Seismic performance of prefabricated steel beam-to-column connections, J. Constr. Steel Res. 102 (2014) 204-216.
[24] Y.Y. Cai, Beam-column connection design of steel frame considering shift away of plastic hinge, Building Structure, 34 (2004) 3-10. (in Chinese)
[25] C.C. Chen, C.A. Lu, C.C. Lin, Parametric study and design of rib-reinforced steel moment connections, Eng. Struct. 27 (2005) 699-708.
[26] L.F. Lu, Y.L. Xu, T.H. Zhou, et al., Experimental research on box strengthened joint connection for weak axis of I-section column-H-shaped beam, Journal of Building Structures, 37 (2016) 73-80.