ABSTRACT

The special concentrically braced frame (SCBF) is an aseismic structure, but its bracing system exhibits brittle failure and premature buckling connected with the weld fracture of the gusset plate and the post-buckling of the braces; thus, maximizing the role of energy dissipation is difficult. Here, this paper proposes a system of double-tube buckling-restrained brace with cast steel connectors for steel SCBFs. The large inelastic deformation of the bracing system is mainly concentrated in the ductile cast connectors under the earthquake, and the degree of buckling and post-buckling of braces can be reduced. Cyclic loading tests were conducted on two groups of specimens with different parameters, then the deformation trend, stress distribution, energy dissipation capacity, and stiffness degradation of the specimens were analyzed. The improved measures of increasing the width–thickness ratio of the energy dissipation plate and stiffener and casting the end right-angle tip tightly for a certain length of cast connector in Group 2 specimens, which overcomes the brittle fracture caused by the crack of the connection segment due to flexural buckling in Group 1 specimen tests, was evaluated. The cast steel connector conducts the main energy dissipation member that exhibits good ductile and energy absorption performance, and the advantages of using improved ductile cast steel connectors to obtain the energy dissipation of BRBs are illustrated. The test results provided direct evidence that the seismic performance of specimens is closely associated with the length of the energy dissipation segment of the cast connector and the overstrength factor of axial force. Also, the strength, rigidity, deformation, and energy dissipation performance of the members can be independently controlled by reasonably designing the cast connector. Our results provide the underlying insights needed to guide the design of the bracing connector.

 

KEYWORDS

Buckling restrained brace, Cast steel connector, Cyclic loading test, Seismic performance, Special concentrically braced frame


REFERENCES

[1] Sabelli R., Roeder C.W. and Hajjar J.F., “Seismic design of steel special concentrically braced frame systems: a guide for practicing engineers”, NEHRP Seismic Design Technical Brief No.8, Gaithersburg, MD, 2013.

[2] Park R., Billings I.J., Clifton G.C., Cousins J. and Walker G., “The Hyogo-Ken Nanbu earthquake (the Great Hanshin Earthquake) of 17 January 1995”, Bulletin of the New Zealand Society for Earthquake Engineering, 28(1), 1-98, 1995.

[3] Astaneh-Asl A., Goel S.C. and Hanson R.D., “Cyclic out-of-plane buckling of double-angle bracing”, Journal of Structural Engineering, 111(5), 1135-1153, 1985.

[4] Goel S.C. and ElTayem A.A., “Cyclic load behavior of angle x-bracing”, Journal of Structural Engineering, 112(11), 2528-2539, 1986.

[5] Rabinovitch J.S. and Cheng J.J.R. “Cyclic behavior of steel gusset plate connectors”, Structural Engineering Report No. 191, University of Alberta, Alberta, Canada, 1993.

[6] Cheng J.J.R, Yam M.C.H. and Hu S.Z., “Elastic buckling strength of gusset plate connectors”, Journal of Structural Engineering, 120(2), 538-559, 1994.

[7] Brown V.L.S. Stability of gusseted connections in steel structures, D.E., Department of Civil Engineering, University of Delaware, Delaware, USA, 1998.

[8] Walbridge S.S., Grondin G.Y. and Cheng J., “An analysis of the cyclic behaviour of steel gusset plate connections”, Journal of Constructional Steel Research, 46(1), 449-450, 1998.

[9] Sheng N., Yam C.H. and Lu V.P., “Analytical investigation and the design of the compressive strength of steel gusset plate connections”, Journal of Constructional Steel Research, 58(11), 1473-1493, 2002.

[10] Tremblay R., “Inelastic seismic response of steel bracing members”, Journal of Constructional Steel Research, 58(5), 665-701, 2002.

[11] Shaback B. and Brown T., “Behaviour of square hollow structural steel braces with end connections under reversed cyclic axial loading”, Canadian Journal of Civil Engineering, 30(4), 745-753, 2003.

[12] Uriz P. and Mahin S.A., “Seismic performance assessment of concentrically braced steel frames”, Proceedings of the 13th World Conference on Earthquake Engineering, Vancouver, BC, Canada, 2004.

[13] Roeder C.W., Lehman D.E., Clark K., Powell J. and Wei C.Y., “Influence of gusset plate connections and braces on the seismic performance of Xbraced frames”, Earthquake Engineering & Structural Dynamics, 40(4), 355-374, 2011.

[14] Roeder C.W., Lumpkin E.J. and Lehman D.E., “A balanced design procedure for special concentrically braced frame connections”, Journal of Constructional Steel Research, 67(11), 1760-1772, 2011.

[15] Lehman D.E. and Roeder C.W., “Improved Seismic Design of Concentrically Braced Frames and Gusset Plate Connections”, American Society of Civil Engineers Structures Congress, Vancouver, British Columbia, Canada, 1-10, 2008.

[16] Yoshino T. and Karino Y., “Experimental study on shear wall with braces: Part 2. Summaries of technical papers of annual meeting”, Architectural Institute of Japan, Structural Engineering Section, Tokyo, Japan, 11, 403-404, 1971.

[17] Clark P.W., Aiken I.D., Kasai K., Ko E. and Kimura I., “Design procedures for buildings incorporation hysteretic damping devices”, Proceedings of the 69th Annual SEAOC Convention, Sacramento, USA, 355–372, 1999.

[18] Nakamura H., Maeda Y. and Sasaki T., “Fatigue Properties of Practical-Scale Unbonded Braces”, Nippon Steel Technical Report, 82, 51-57, 2000.

[19] Koetaka Y., Narihara H. and Tsujita O., “Experimental study on buckling restrained braces”, Proceedings of the Sixth Pacific Structural Steel Conference, Beijing, China, 15-17, 2001.

[20] Wakabayashi M., Nakamura T., Kashibara A., Morizono T. and Yokoyama H, “Experimental study of elasto-plastic properties of precast concrete wall panels with built-insulating braces”, In: Summaries of Technical Papers of Annual Meeting, Architectural Institute of Japan, Structural Engineering Section, Tokyo, Japan, 10, 1041-1044, 1973.

[21] Mochizuki S., Murata Y., Andou N. and Takahashi S., “Experimental study on buckling of unbonded braces Under axial forces: Parts 1&2. Summaries of technical papers of annual meeting” , Architectural Institute of Japan, Structural Engineering Section, Tokyo, Japan, 1623-1626, 1979.

[22] Sridhara B.N., “Sleeved column-as a basic compression member”, Proceedings of the 4th International conference on steel structures and space frames, Singapore, 181-188, 1990.

[23] Iwata M., Kato T. and Wada A., “Buckling-restrained braces as hysteretic dampers”, Proceedings of the Behavior of Steel Structures in Seismic Areas: STESSA 2000, Montreal, Canada, 33-38, 2000.

[24] Xie L.Q., Wu J., Shi J.H. and Zhu Y.Q., “Influence of the core-restrainer clearance on the mechanical performance of sandwich buckling-restrained braces”, Advanced Steel Construction, 16(1), 37-46, 2020.

[25] Tada M., Kuwahara S. and Yoneyama T., “Horizontally loading test of the steel frame braced with double-tube members”, Annual Technical Papers of Steel Structures, 1, 203-208, 1993.

[26] Lai J.W. and Tsai K.C., “Research and application for buckling restrained braces in Taiwan”, 2004 ANCER Annual Meeting: The Sheraton Princess Kaiulani, Honolulu, Hawaii, 2004.

[27] Yin Z.Z. and Wang X.L., “Finite component analysis of constrained buckling support with contact ring”, Journal of Lanzhou University of Technology, 34(5), 122-126, 2008. (in Chinese)

[28] Yin Z.Z. and Bu F.C., “Overall stability analysis of improved buckling restrained braces”, The Open Civil Engineering Journal, 10(1), 61-75, 2016.

[29] Yin Z.Z., Chen W., Chen S.L. and Wang X.L., “Experimental study on buckling support of improved double steel tube”, Journal of Building Structures, 35(09), 90-97, 2014.

[30] Fleischman R.B., Sumer A. and Li X.J., “Development of modular connections for steel special moment frames”, American Society of Civil Engineers Structures Congress 2004, Nashville, Tennessee, United States, 1-9, 2004.

[31] Fleischman R.B. and Sumer A., “Optimum arm geometry for ductile modular connectors”, Journal of Structural Engineering, 132(5), 705-716, 2006.

[32] Oliveira J.C.D., Packer J.A. and Christopoulos C., “Cast steel connectors for circular hollow section braces under inelastic cyclic loading”, Journal of Structural Engineering, 134(3), 374-383, 2008.

[33] Gray M.G., “Cast steel yielding brace system for concentrically braced frames”, School of Graduate Studies - Theses, 2012.

[34] Khan K. and Yan J.B., “Numerical studies on the seismic behaviour of a prefabricated multi-storey modular steel building with new-type bolted joints”, Advanced Steel Construction, 17(1), 1-9, 2021.

[35] Hou Z.X., Gong C., Zhang Y., Sun Y.Z., Jiang J. and Li G.Q., “Seismic behavior of bolted connections with slot bolt holes at ambient and elevated temperature”, Advanced Steel Construction, 14(4), 651-667, 2018.

[36] Liu J.B. Theoretical study on design of anti-buckling support and buckling support frame, D.E., Tsinghua University, Beijing, China, 2005.

[37] GB50017-2003. Code for design of steel structures, China Architecture & Building Press, Beijing, China, 2006.

[38] GB/T 228–2002. Metallic materials-tensile testing at ambient temperature, China Standard Press, Beijing, China, 2002.