Advanced Steel Construction

Vol. 19, No. 1, pp. 46-51 (2023)


 STUDY ON FIRE RESISTANCE OF BOX-TYPE COMPOSITE WALLS

 

Yan-Qing Fu 1, 2, Qing-Qing He 3, Guang-Chong Qin 3, Tao Lan 3, * and Ran Li 3

1 Southwest Jiaotong University, Sichuan, China

2 Central Research Institute of Building and Construction Co., Ltd, MCC Group, Beijing, China

3 China Shipbuilding Industry Corporation International Engineering Co., Ltd., Beijing, China

* (Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)

Received: 20 July 2022; Revised: 22 August 2022; Accepted: 10 January 2023

 

DOI:10.18057/IJASC.2023.19.1.7

 

View Article   Export Citation: Plain Text | RIS | Endnote

ABSTRACT

The fire resistance limit value of box-type composite walls is one of the important parameters for applying this system. To this end, this article selects different refractory structural measures for the composite wall and analyzes the parameters in each part of the fire-resistant structure, including rock wool thickness, keel spacing, number of opening rows in the keel, gypsum board layers and thickness, etc. The results show that the thickness of rock wool, gypsum board layers and thickness, type of cladding plates and the number of layers, the axial compression ratio have significant influence on the fire endurance. The keel distance and the number of openings rows are almost unaffected. Based on the above analysis, the fire resistance optimization design method and fire resistance calculation formulas of the composite wall are proposed to provide theoretical support for the fire protection design of the box-type steel structural system.

 

KEYWORDS

Box-type steel structure, Fire resistance, Parametric analysis, Fire resistant optimization design


REFERENCES

[1] Men J.J., He Q.Q., Lan T., Guo C.L., Jiang Z.Q., “Shaking table model test design for box-type steel structure residence”, Industrial Architecture, 2018, 48(09), 9-14+82.

[2] Lan T., Guo C.L., Men J.J., He Q.Q., Zhao T., Wang L.Y., “Shake table model test of prefabricated box-type steel structure house”, Industrial Architecture, 2018, 48(09), 1-8.

[3] Lan T., Song Z., Men J.J., Zhao T.Z., Zhao T., Wang L.Y., “Experimental study on seismic performance of box-type steel structure modules reinforced with reinforced corners”, Industrial architecture, 2018, 48 (09), 15-21.

[4] GB 50011-2010, Code of seismic design for buildings 2016, Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China, 2016.

[5] Zhao T.T., “Study on seismic performance of wall in bottom reinforced area of box-plate steel structure residence”, Xi’an University of Architecture & Technology, 2018.

[6] Li G.Q., Han L.H., Lou G.B., Jiang S.C., Fire resistance design of steel structure and steel-concrete composite structure, China, 2006.

[7] Li G.Q.et al, Steel structure resistance calculation and design, China, 1999.

[8] T. T. Lie, M. Chabot, “Method to predict the fire resistance of circular concrete filled hollow steel columns”, Journal of Fire Engineering, 1990, 2(4), 111-126.

[9] GB/T 9978-2008, Fire-resistance tests-elements of building, Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China, 2008.

[10] Chen W., “Fire resistance test and theoretical research of cold-formed steel bearing composite wall”, Southeast University, 2014.

[11] JGJ 3-2010, Technical specification for concrete structures of tall building, Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China,2010.

[12] GB 50016-2014, Code for Fire Protection Design of Building 2018, Ministry of Housing and Urban-Rural Development of the People's Republic of China, Beijing, China, 2018.