Vol. 19, No. 4, pp. 403-410 (2023)
CONFORMATION AND STATIC PERFORMANCE ANALYSIS OF
PENTAGONAL THREE-FOUR STRUT HYBRID OPEN-TYPE CABLE DOME
Hui Lv 1, 2, *, De-Wang Liu 1, 4, Shi-Lin Dong 2, 3 and Yan-Fen Zhong 1, 4
1 College of Civil Engineering and Architecture, Nanchang Hangkong University, Nanchang 330063, China
2 Space Structures Research Center, Zhejiang University, Hangzhou 310058, China
3 Zhejiang Provincial Key Laboratory of Space Structures, Zhejiang University, Hangzhou 310058, China
4 Nanchang Hangkong University Smart Construction Research Center, Nanchang 330063, China
*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 6 July 2023; Revised: 9 September 2023; Accepted: 12 September 2023
DOI:10.18057/IJASC.2023.19.4.9
View Article | Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
Traditional cable domes exhibit many defects, such as irregular grids and weak circumferential stiffness. This paper proposes a new cable dome and elaborates on the topological form of the new cable dome. Furthermore, the pre-stress state of the structure is deduced by establishing the nodal equilibrium equations. In addition, load states analysis and parametric analysis were conducted using finite element simulations in ANSYS software. The results show that the pre-stress distribution of this structure is reasonable because of the regular grids. Compared to traditional cable domes, the new design shows superior static performance and enhanced circumferential stiffness. As a result, the cables hardly slack under different load conditions. Moreover, it can improve structural stiffness by appropriately adjusting the initial pre-stress, rise-span and thickness-span ratios. Finally, recommended ranges of the above parameters are provided, offering valuable engineering design guidance.
KEYWORDS
Cable dome, Static performance, Parametric analysis, Initial pre-stress, Rise-span ratio, Thickness-span ratio
REFERENCES
[1] Hui. Deng, M.R. Zhang, H.C. Liu, et al., "Numerical Analysis of the Pretension Deviations of a Novel Crescent-shaped Tensile Canopy Structural System", Engineering Structures, 119, 24-33, 2016.
[2] T.N. Zhang, J.Y. Zhao, "Seismic Resilience Assessment of a Single-layer Reticulated Dome During Construction", Advanced Steel Construction, 19(1), 77-85, 2023.
[3] X.Y. Fu, Y. Gao, C.Z. Xiao, et al., "Horizontal Skyscraper: Innovative Structural Design of Shenzhen VANKE Center", Journal of Structural Engineering, 138(6), 663-668, 2012.
[4] S.J. Sun, K.H. Mei, Y.M. Sun, et al., "Structural Performance of Super-Long-Span Cable-Stayed Bridges with Steel and CFRP Hybrid Cables", Arabian Journal for Science and Engineering, 45(5), 3569-3579, 2019.
[5] M.M. Ding, Bin. Luo, S.Y. Ding, et al., "Experimental Investigation and Numerical Simulation of a Levy Hinged-Beam Cable Dome", Buildings, 11(3), 2021.
[6] H.H. Ma, Y.Y. Ma, Feng. Fan, et al., "Seismic performance of single-layer spherical reticulated shells considering joint stiffness and bearing capacity", Advanced Steel Construction, 18(2), 604-616, 2022.
[7] Jian. Lu, S.D. Xue, X.Y. Li, et al., "Segmented Assembly Construction Forming Method Without Brackets of Spatial Cable-Truss Structure Without Inner Ring Cables", Advanced Steel Construction, 18(3), 687-698, 2022.
[8] L.M. Tian, J.P. Wei, Q.X. Huang, et al., "Collapse-Resistant Performance of Long-Span Single-Layer Spatial Grid Structures Subjected to Equivalent Sudden Joint Loads", Journal of Structural Engineering, 147(1), 2021.
[9] Jie. Wu, "Cable Force Characteristic Test of Bidirectional Beam String Structure after Cable Shape Optimization", Journal of Tianjin University(Science and Technology), 49(1), 86-95, 2016.
[10] Z.L. Zong, Z.X. Guo, F.W. Lv, "Experimental Research on A Composite Structure of Cable Dome and Rigid Shell", Journal of Zhejiang University (Engineering Science ), 29(7), 75-79, 2013.
[11] Feng. Fan, Li. Cai, "Static Analysis of Inclined-strut System Cable Dome", Journal of Harbin Institute of Technology, 40(6), 841-845, 2008.
[12] Yu. Fang, C.W. Huang, T.W. Zhou, et al., "Parameter Analysis of Rigid Kiwitt Dome Structure", Industrial Construction, 46, 313-316, 2016.
[13] Hui. Wu, D.Q. Cen, B.Q. Gao, "Approximate Optimization and Performance Analysis of Rigid Cable Dome Structure", Journal of Zhejiang University (Engineering Science ), 45(11), 1966-1971, 2011.
[14] A.L. Zhang, C.Q. Wu, Y.X. Zhang, "Analysis on the Structure and Initial Prestress of T-Type Three Strut Cable Dome", Journal of Beijing University of Civil Engineering and Architecture, 37(1), 01-07, 2021.
[15] S.L. Dong, W.G. Chen, Yuan. Tu, et al., "Configuration and Prestressing Distribution of the Honeycomb-type Cable Dome with Three Struts", Engineering Mechanics, 36(9), 128-135, 2019.
[16] S.L. Dong, Y.D. Wang, H.C. Liu, "Structural Form Innoivation and Initial Prestress Analysis on Drum-shaped Honeycomb-type Cable Domes with Multi-strut Layout ", Spatial Structures, 28(3), 3-15, 2022.
[17] A.L. Zhang, W.J. Yuan, Y.X. Zhang, et al., "Static Performance Analysis of Alternated Cable Dome with Single and Double Brace Struts", Journal of Vibration and Shock, 41(12), 321-330, 2022.
[18] H.Z. Bao, S.L. Dong, "Analyses on Functions of Static Mechanic in Bird-nest Cable Dome", Building Structure, 38(11), 11-13+39, 2008.
[19] S.L. Dong, W.G. Chen, Yuan. Tu, et al., "Analysis of Multi-parameter Sensitivity and Prestressing Force Distribution of Sunflower-type Cable Dome with Double struts", Journal of Tongji University(Natural Science), 47(6), 739-746+801, 2019.
[20] A.L. Zhang, L.N. Zhu, Y.X. Zhang, et al., "Configuration and Prestress Analysis Method of Star Shaped Tetrahedral Cable Dome", Journal of Vibration and Shock, 40(9), 84-91, 2021.
[21] S. Kmet, M. Mojdis, "Adaptive Cable Dome", Journal of Structural Engineering, 141(9), 2015.
[22] M.S. Chen, Ling. Yue, "Static Performance Analysis of Geiger-type Cable Dome", Journal of Hunan Institute of Engineering(Natural Science Edition), 25(4), 73-77, 2015.
[23] Shu. Yao, Fan. Feng, "Static Analysis of K6 Suspen·Dome Structure", Building Structure, 38(2), 43-46, 2008.
[24] R.W. Tang, X.Z. Zhao, Z.Y. Shen, "Factor Analysis of Geiger Cable Dome", Building Science, 29(1), 11-14+10, 2013.
[25] Yue. Feng, X.F. Yuan, A. Samy, "Analysis of New Wave-curved Tensegrity Dome", Engineering Structures, 250, 113408, 2022.
[26] W.T. Yan, H.B. Zhang, "Analysis of Form-finding of Cable Dome Supporting Membrane Structures", Steel Construction, 23(4), 1-3, 2008.
[27] L.L. Zhang, Chong. Ma, Yuan. Cao, et al., "Structural Stiffness of Tensioned Membrane Structure and Its Effect on the Structure Properties", Building Structure, 47(21), 25-29, 2017.
[28] Yue. Yin, W.J. Chen, J.H. Hu, et al., "In-situ Measurement of Structural Performance of Large-span Air-supported Dome under Wind Loads", Thin-Walled Structures, 169, 108476, 2021.
[29] Zhong. Fan, Zhe. Wang, Jie. Tang, "Analysis on Temperature Field and Determination of Temperature upon Healing of Large-span Steel Structure of the National Stadium", Journal of Building Structures, 28(2), 32-40, 2007.
[30] C.H. Ye, J.Z. Lv, Z.G. Lin, "A Study on New Extreme Maximum Air Temperature in China", Meteorological Monthly, 34(11), 3-6, 2008.
[31] Y.J. Zhao, Cheng. Chang, C.Y. Bai, et al., "Climate Characteristic and Change of Mohe Extreme Temperature", Meteorological Monthly, 35(3), 94-98, 2009.
[32] A.L. Zhang, X.C. Liu, Shan. Feng, et al., "Temperature Response Analysis of Large-Span Cable Dome Structure", Journal of Building Structures, 33(4), 40-45, 2012.