Vol. 20, No. 3, pp. 280-291 (2024)
BEHAVIOUR OF LOCALLY DAMAGED Q355 STEEL EQUAL ANGLES
SUBJECTED TO COMPRESSION
Song-Yang He 1, Xing Huang 1, Xiang-Yun Liu 1, Zhong Li 1, Tao Gong 1, Hui-Qiang Yan 2, 3 and Shao-Bo Kang 2, 3, *
1 Southwest Electric Power Design Institute Co., LTD., China Power Engineering Consulting Group, 16 Dongfeng Road, Chenghua District, Chengdu 610021, China
2 Key Laboratory of New Technology for Construction of Cities in Mountain Area (Chongqing University), Ministry of Education, Chongqing 400045, China
3 School of Civil Engineering, Chongqing University, Chongqing 400045, China
*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 7 October 2023; Revised:27 February 2024; Accepted: 4 March 2024
DOI:10.18057/IJASC.2024.20.3.7
View Article | Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
Steel angles in transmission towers may experience corrosion in the service life due to bad exposure conditions. However, limited experimental results are available about the remaining load capacity of corroded steel angles in compression at present. This paper presents experimental tests, numerical simulations and design method of steel angles with local damages at the mid-height or end induced by corrosion. Five groups of steel angles with different depths of local damages at different locations were tested under axial compression in the experimental programme, and the load capacity and failure mode of steel angles were obtained. Numerical models are developed and validated using test data, and parametric studies are conducted to investigate the influence of depth and slenderness of steel angles on ultimate load. Moreover, design equations are developed for locally damaged steel angles, and comparisons with numerical results show yield reasonably accurate estimations of the ultimate load. Comparisons are also made between the calculated result using the developed equation and existing design curves in the relevant code to demonstrate the effect of local damage on the buckling coefficient of steel angles. It shows that the local damage at the mid-height or the end of steel angles could significantly reduce the buckling coefficient, and therefore, it has to be considered when evaluating the ultimate load of steel angles in transmission towers in service.
KEYWORDS
Steel equal angles, Local damage, Axial compression, Experimental test, Numerical simulation, Design equation
REFERENCES
[1] S.H. Xu, Z.X. Zhang, G.C. Qin, Study on the seismic performance of corroded H-shaped steel columns, Engineering Structures 191 (2019) 39-61.
[2] Y. Sharifi, S. Tohidi, J.K. Paik, Ultimate compressive strength of deteriorated steel web plate with pitting and uniform corrosion wastage, Sci. Iran. 23(2) (2016) 486-499.
[3] A. Cinitha, P.K. Umesha, N.R. Iyer, An overview of corrosion and experimental studies on corroded mild steel compression members, KSCE Journal of Civil Engineering 18(6) (2014) 1735-1744.
[4] T. Kaita, J. Appuhamy, K. Itogawa, M. Ohga, K. Fujii, Experimental Study on Remaining Strength Estimation of Corroded Wide Steel Plates under Tensile Force, 12th East Asia-Pacific Conference on Structural Engineering and Construction (EASEC), Hong Kong, PEOPLES R CHINA, 2011.
[5] V. Sarveswaran, J.W. Smith, D.I. Blockley, Reliability of corrosion-damaged steel structures using interval probability theory, Structural Safety 20(3) (1998) 237-255.
[6] H. Tang, J.X. Peng, C.S. Cai, D.D.K. Lee, Test, 3D Scanning and FE Study on Flexural Behavior of Q550E HPS Beams Subjected to Local Corrosion at Mid-Span Region, International Journal of Steel Structures 22(5) (2022) 1452-1473.
[7] Y.D. Wang, S.H. Xu, A.B. Li, Flexural performance evaluation of corroded steel beams based on 3D corrosion morphology, Structure and Infrastructure Engineering 16(11) (2020) 1562-1577.
[8] J. Peng, L. Xiao, J. Zhang, C.S. Cai, L. Wang, Flexural behavior of corroded HPS beams, Engineering Structures 195 (2019) 274-287.
[9] Z.X. Zhang, S.H. Xu, H. Wang, B.A. Nie, C. Su, Flexural buckling behavior of corroded hot-rolled H-section steel beams, Engineering Structures 229 (2021).
[10] Y. Chai, J.X. Peng, L.F. Xiao, X.H. Liu, J.R. Zhang, Fatigue Behavior of High-Performance Steel Beams Subjected to Different Corrosion Conditions, International Journal of Steel Structures 23(4) (2023) 1105-1118.
[11] X.H. Liu, J.R. Zhang, Experimental Study on Effect of Corrosion on Flexural Load-carrying Capacity of Q550E High-performance Steel Girder, Zhongguo Gonglu Xuebao/China Journal of Highway and Transport 32(11) (2019) 184-191and201.
[12] Z.W. Zhao, S.J. Mo, Q.Q. Xiong, H.Q. Liu, B. Liang, Moment capacity of H-section steel beam with randomly located pitting corrosion, Probabilistic Engineering Mechanics 66 (2021).
[13] Z.W. Zhao, L.M. Tang, N. Zhang, Q. Cai, S.J. Mo, B. Liang, Shear capacity of H-shaped steel beam with randomly located pitting corrosion, Applied Ocean Research 115 (2021).
[14] J. Sheng, J.W. Xia, H.F. Chang, Bending Behavior of Corroded H-Shaped Steel Beam in Underground Environment, Appl. Sci.-Basel 11(3) (2021).
[15] S. Xu, B. Nie, H. Zhang, Time-dependent Reliability Analysis of Corroded Steel Beam Based on Probability Density Evolution Theory, Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences 47(7) (2020) 75-83.
[16] B. Wang, W.Z. Huang, S.S. Zheng, Study on Restoring Force Performance of Corrosion Damage Steel Frame Beams under Acid Atmosphere, Applied Sciences-Basel 9(1) (2019).
[17] K.K. Toledo, H.S. Kim, Y.S. Jeong, I.T. Kim, Residual Compressive Strength of Short Tubular Steel Columns with Artificially Fabricated Local Corrosion Damage, Materials 13(4) (2020).
[18] Y.D. Wang, T. Shi, B. Nie, H. Wang, S.H. Xu, Seismic performance of steel columns corroded in general atmosphere, Steel and Composite Structures 40(2) (2021) 217-241.
[19] A. Hussain, Y.-P. Liu, S.-L. Chan, Finite Element Modeling and Design of Single Angle Member Under Bi-axial Bending, Structures 16 (2018) 373-389.
[20] Q. Zhang, J.N. Wen, Q. Han, Z.F. Wang, J.B. Sun, Seismic performance evaluation of steel circular hollow section bridge piers with corroded ends, Bulletin of Earthquake Engineering (2023).
[21] Z.X. Zhang, S.H. Xu, B. Nie, R. Li, Z. Xing, Experimental and numerical investigation of corroded steel columns subjected to in-plane compression and bending, Thin-Walled Structures 151 (2020).
[22] S.S. Zheng, X.H. Zhang, X.R. Zhao, Experimental investigation on seismic performance of corroded steel columns in offshore atmospheric environment, Structural Design of Tall and Special Buildings 28(4) (2019).
[23] B. Nie, S.H. Xu, H.J. Zhang, Z.X. Zhang, Experimental and numerical studies on the behaviour of corroded cold-formed steel columns, Steel and Composite Structures 35(5) (2020) 611-625.
[24] Z.-L.D. A.H.A. Abdelrahman, Yao-Peng Liu, S.-L.C. ⁎ Stability design of single angle member using effective stress-strain method, Structures 20 298-308.
[25] K. Oszvald, P. Tomka, L. Dunai, The remaining load-bearing capacity of corroded steel angle compression members, Journal of Constructional Steel Research 120 (2016) 188-198.
[26] Y. Huang, Z.G. Su, B.R. Zhu, Y.X. Chen, T. Wan, Z.X. Tuo, The influence of corrosion on the bearing capacity characteristics of overhead transmission line tower, Nonferrous Metals Science and Engineering(2023) 1-11.
[27] ABAQUS, Analysis user's manual version 6.13, ABAQUS Inc2013.
[28] Standard for design of steel structures (GB50017-2017), Standards Press of China, Beijing, 2017(in Chinese).
[29] M. Chen, W. Fang, H. Huang, Static behavior of corroded concrete-filled steel tubular members by simulating acid rain solution, Engineering Mechanics 37(2) (2020) 34-43.