Vol. 21, No. 4, pp. 316-326 (2025)
SEISMIC PERFORMANCE OF END-PLATE CONNECTION IN
A NARROW-FLANGE H-SHAPED BEAM-COLUMN
Wei-Hui Zhong 1, 2, *, Di Wu 1, Zheng Tan 1, 2, Ying-Zhao Qiu 1, Dong-Ping Yang 1, Chen-Hao Ren 3 and Le Deng 1
1 School of Civil Engineering, Xi’an University of Architecture and Technology, Xi’an 710055, China
2 Key Lab of Structural Engineering and Earthquake Resistance, Ministry of Education, Xi’an University of Architecture and Technology, Xi’an 710055, China
3 Shaanxi Architecture Science Research Institute Company Limited, Xi’an 710082, China
*(Corresponding author: E-mail:This email address is being protected from spambots. You need JavaScript enabled to view it.)
Received: 9 March 2024; Revised: 15 January 2025; Accepted: 6 February 2025
DOI:10.18057/IJASC.2025.21.4.4
View Article |
Export Citation: Plain Text | RIS | Endnote |
ABSTRACT
To improve the seismic performance of both low-rise and multi-story steel residential structures, and to address the ongoing issue of column protrusion, this paper introduces a cross-shaped end-plate connection joint. This joint is designed for narrow-flange H-beams and has been evaluated through quasi-static tests for failure modes, hysteresis curves, and load-bearing capacity. Experimental findings indicate that this joint serves as a semi-rigid connection, offering exceptional ultimate rotational capacity, energy dissipation, and ductility. These features make it well-suited for use in mid- and low-rise seismic steel frame structures. To deepen our understanding of the joint's seismic performance, a numerical model was established using ABAQUS software. The validity of this modeling approach was confirmed by comparing it with experimental results. Several variables were analyzed for their impact on the joint's seismic performance, including axial compression ratio, column web thickness, skin plate thickness, column-flange reinforcement plate thickness, and beam end-plate thickness. Our analysis reveals that an increase in the axial compression ratio makes the negative slope of the joint's hysteresis curve more pronounced. This suggests that the axial compression ratio should not exceed 0.4. Additionally, the use of skin plates led to a 26.3% increase in joint yield displacement and a 14.9% increase in ultimate displacement. The incorporation of column-flange reinforcement plates boosted both the yield and peak strength by 15.5% and 14.2%, respectively. Consequently, we recommend using skin and reinforcement plate thicknesses that are 0.5 and 0.8 times the thickness of the end-plate, respectively. By carefully selecting the appropriate parameters for these components, this study offers valuable insights and guidelines for the practical implementation of beam-column joints in low-rise and multi-story steel residential structures.
KEYWORDS
Narrow-flange H-shaped, Beam column, End-plate connections, Seismic performance, Prefabricated structures
REFERENCES
[1] Hao J.P., Sun X.L., Xue Q., et al., “Research and Applications of prefabricated Steel structure building Systems”, Engineering Mechanics, 34(01), 1-13, 2017. (in Chi-nese)
[2] Zhou X.H., Wang Y.H., “Status, problems and countermeasures of industrialization development of steel structural residence in China”, Journal of Civil Engineering, 52(01), 1-7, 2019. (in Chinese)
[3] Wang J., Brian U., Thai H.T., et al., “Behaviour and design of demountable beam-to-column composite bolted joints with extended end-plates”, Journal of Constructional Steel Research, 144, 221-235, 2018.
[4] D'Aniello M., Tartaglia R., Costanzo S., et al., “Seismic design of extended stiffened end-plate joints in the framework of Eurocodes”, Journal of Constructional Steel Research, 218, 512-527, 2017.
[5] Haghollahi A., Jannesar R., “Cyclic Behavior of Bolted Extended End-Plate Mo-ment Connections with Different Sizes of End Plate and Bolt Stiffened by a Rib Plate”, Civil Engineering Journal, 4(01), 200-211, 2018.
[6] Hoang V.L., Jaspart J.P., Demonceau J.F., “Hammer head beam solution for beam-to-column joints in seismic resistant building frames”, Journal of Construc-tional Steel Research, 103, 49-60, 2014.
[7] Chen S.F., “The Strength and stiffness of bolted connection in Portal Frame”, Steel structure, 15(01), 6-11, 2000. (in Chinese)
[8] Guo B., Gu Q., Liu F., “Experimental study on hysteretic behavior of beam-column end-plate joints”, Journal of Building Structure, 23(03), 8-13, 2002. (in Chinese)
[9] Li G.Q., Duan L., Lu Y., “Experimental and theoretical study of bearing capacity for extended endplate connections between rectangular tubular columns and H-shaped beams with single direction bolts”, Journal of Building Structure, 36(09), 91-100, 2015. (in Chinese)
[10] Wang Y., Li H.J., Li J.F., et al., “Analysis of initial stiffness and structural internal forces of semi-rigid beam-column joint connection”. Engineering Mechanics, 20(06), 65-69, 2003. (in Chinese)
[11] Tong G.S., Zhao W., “Design Approach of Stiffeners in Extended End Plate Con-nections and Finite Element Analysis”, Journal of Shenyang Jianzhu University (Natural Science), 21(06), 616-620, 2005. (in Chinese)
[12] Zhong W.H., Zhao M.J., Zhou L., et al., “Seismic performance of a narrow flange H-beam-to-column full-bolt end-plate weak-axis connection”. Structures, 46, 637-653, 2022.
[13] “Standards for design of steel structures: GB 50017—2017”, Beijing: China Ar-chitecture & Building Press, 2017. (in Chinese)
[14] Guo B., Guo B.S., Zhang H.W., “M-θ relations for extended end-plate beam-column bolted connections”, Journal of Shandong Institute of Arch and Eng, 16(03), 1-5, 2001. (in Chinese)
[15] Solhmirzaei A., Tahamouli R.M., Hosseini H.B., “A new detail for the panel zone of beam-to-wide flange column connections with endplate”, Structures, 34, 1108-1123, 2021.
[16] AISC (American Institute of Steel Construction). Prequalified connections for special and intermediate steel moment frames for seismic applications. AN-SI/AISC 358–16, Chicago, IL, 2016.
[17] Tartaglia R., D'Aniello M., Gian A.R., et al., “Full strength extended stiffened end-plate joints: AISC vs recent European design criteria”, Engineering Structures, 159, 155-171, 2018.
[18] Technical code for steel structure of light-weight building with gabled frames GB 51022—2015 [S] Beijing: China Architecture & Building Press, 2017. (in Chinese)
[19] Lu L.F., Li C.C., Liu Z.L., et al., “Finite element analysis of the strengthen-joint region connection of I-shaped columns for the strong axis”, Advanced Civil, Urban and Environmental Engineering, 157, 123-131, 2014.
[20] “Earthquake resistant design code GB 50011-2010”, Beijing: China Architecture & Building Press, 2016. (in Chinese)
[21] “Steel and steel products—Location and preparation of samples and test pieces for mechanical testing GB/T 2975-2018”, Beijing: Standards Press of China,2018. (in Chinese)
[22] FEMA-267A. Interim Guideline: Advisory No. 1, Supplement to FEMA-267A[R]. Rep. SAC Joint Venture, Sacramento, California, 1997.
[23] Tan Z., Zhong W.H., Tian L.M., et al., “Quantitative assessment of resistant contri-butions of two-bay beams with unequal spans”, Engineering Structures, 242, 112-445, 2021.
[24] Zhong W.H., Tan Z., Tian L.M., et al., “Collapse resistance of composite beam-column assemblies with unequal spans under an internal column-removal scenario”, Engineering Structures, 206, 110-143, 2020.
[25] Tan Z., Zhong W.H., Gao Y., et al., “Collapse behavior of unequal-span multistory composite frames under the scenario of removing an internal column”, Journal of Structural Engineering, 150(12), 04024173, 2024.
[26] ABAQUS, Analysis User’s Manual, 6.17, ABAQUS, Inc., Dassault Systemes, USA, 2017.